BLDGM - CONAPOXY AD-15 PART A
- MSDS: BLDGM
- Manufacturer: CONAP INC
- Product Name: CONAPOXY AD-15 PART A
- National Stock Number: 8010-00N018136
Product Identification
Product ID:CONAPOXY AD-15 PART A
MSDS Date:06/06/1989
FSC:8010
NIIN:00N018136
Kit Part:Y
MSDS Number: BLDGM
Responsible Party
OLEAN, NY 14760
US
Emergency Phone: 716-372-9650
Info Phone: 716-372-9650
Cage: DO146
Contractor
Telephone: 716-372-9650
Cage: 16245
Ingredients
CANCER HAZ TO HUMANS. RESULTS OF MUTAGENICITY
RTECS: 9999999ZZ
TO BE NEGATIVE IN SOME INVITRO ("TEST TUBE")
RTECS: 9999999ZZ
NOT ESTABLISHED. NO SPECIFIC ANTIDOTE. TREATMENT
RTECS: 9999999ZZ
PHENOL, 4,4'-ISOPROPYLIDENEDI-,POLYMER WITH 1-CHLORO-2,3-
CAS: 25068-38-6
RTECS: SL6475000
Fraction By Weight: 60-80%
PROPANE, 1,2-EPOXY-3-(O-TOLYOXY)-; (CRESYL GLYCIDYL ETHER)
CAS: 2210-79-9
RTECS: TZ3700000
Fraction By Weight: 20-40%
SILICON DIOXIDE, AMORPHOUS; (SILICON DIOXIDE). OTHER REC
CAS: 7631-86-9
Fraction By Weight: <10%
MAY CAUSE DERMAT. TREAT AS ANY CONT
RTECS: 9999999ZZ
INJURY IS
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50(ORAL,RAT) >2000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: NO GUIDE FOR CONTROL KNOWN. NOT
CONSIDERED A PROBLEM UNLESS HEATED TO HIGH TEMP. INGEST: LOW ACUTE
ORAL TOX. EYE: MINOR TRANSIENT IRRIT. NO CORNEAL INJURY LIKELY.
SKIN: ONLY MINOR TRANSIENT IRR IT, MAY BE A SKIN SENSITIZER. SKIN
ABSORP: NOT LIKELY TO BE ABSORBED THRU SKIN IN TOX AMTS. MAY (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CAUSE DERMAT. KNOWN/SUSPECTED SKIN
SENSITIZER. MAY CAUSE MINOR IRRIT TO EYES, INJURY IS UNLIKELY.
EXPOS TO LOW MOLECULAR WEIGHT EPOXY RESINS OF THIS TYPE ARE NOT
ANTICIPATED TO CAUSE ANY SIG NIFICANT ADVERSE EFTS. A POORLY
CHARACTSAMPLE OF LOW MOLECULAR WEIGHT EPOXY RESIN OF THIS TYPE
(DIGLYCIDYL (SUPP DATA)
First Aid
First Aid:EYE: IRRIGATION OF EYE IMMED W/WATER FOR AT LEAST 15 MIN IS
GOOD SAFETY PRACTICE. CALL MD. SKIN: CONT WILL PROBABLY CAUSE NO
MORE THAN IRRIT. WASH OFF IN FLOWING WATER/SHOWER. WASH CLOTHING
BEFORE REU SE. INHAL: REMOVE TO FRESH AIR IF EFFECTS OCCUR. CALL
MD. INGEST: LOW IN TOX. INDUCE VOMIT IF LRG AMT ARE INGEST. NOTE TO
MD: EYES: INJURY IS UNLIKELY. STAIN FOR EVIDENCE OF CORNEAL
INJURY.(SEE ING 4)
Fire Fighting
Flash Point Method:PMCC
Flash Point:>485F,>252C
Extinguishing Media:DRY CHEMICAL, CO2, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
WHEN POTENTIAL FOR EXPOS TO VAPS OR PRODS OF COMBUST EXISTS. USE
WATER SPRAY TO COOL FIRE-EXPSD CNTNRS.
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:CONSULT SPECIAL HANDLING FOR PROPER PROTECTIVE
EQUIPMENT. SOAK UP IN ABSORBENT MATERIAL OR SCRAPE UP. RESIDUAL CAN
BE REMOVED WITH NON-FLAMMABLE SOLVENT SUCH AS METHYLENE CHLORIDE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PRACTICE GOOD CAUTION.
Other Precautions:MATERIAL MAY PRESENT A DUST HAZARD IF CUT, GROUND, OR
MACHINED AFTER CURING.
Exposure Controls
Respiratory Protection:NONE NORMALLY NEEDED UNDER NORMAL CONDITIONS.
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:GOOD ROOM VENTILATION NORMALLY ADEQUATE FOR MOST
OPERATIONS. MECHANICAL VENTILATION RECOMMENDED.
Protective Gloves:RUBBER OR IMPERVIOUS PLASTIC GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CLEAN, BODY COVERING CLOTHING.
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE.
Supplemental Safety and Health
EFTS OF OVEREXP: ETHER OF BISPHENOL A) HAS BEEN RPTD TO PRODUCE SKIN
CANCER IN A HIGHLY SENSITIVE TRAIN OF MICE. HOWEVER, HIGH LEVS OF
IMPURITIES (INCL A KNOWN ANIMAL SKIN CARCIN) COMPROMISE THE VALID
ITY OF THE FINDINGS. EPOXY RESIN THAT IS REPRESENTATIVE OF CURRENT
MFG PROCESSES IS NOT BELIEVED TO BE A (SEE ING 7)
Chemical Properties
HCC:N1
Solubility in Water:NONE
Appearance and Odor:VISCOUS LIQUID NO DISTINCT ODOR.
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:YES
BASE
Stability Condition to Avoid:EXCESSIVE HEATING DEGRADES RESIN.
Hazardous Decomposition Products:CO2, CO FROM THERMAL DECOMPOSITION.
Conditions to Avoid Polymerization:MASSES OF MORE THAN 1 LB OF PROD
PLUS ALIPHATIC AMINE WILL CAUSE IRREVERSIBLE POLYM WITH
CONSIDERABLE HEAT BUILDUP.
Disposal
Waste Disposal Methods:DISPOSE OF ACCORDING TO ANY LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.